메뉴 건너뛰기
Library Notice
Institutional Access
If you certify, you can access the articles for free.
Check out your institutions.
ex)Hankuk University, Nuri Motors
Log in Register Help KOR
Subject

Evaluation of Condensation Prevention Performance for Apartment Built-in Furniture with Vent-type Moldings in Winter
Recommendations
Search
Questions

통기형 몰딩 적용에 따른 공동주택 붙박이장의 동계 결로방지성능 평가

논문 기본 정보

Type
Academic journal
Author
Lee, Chae-Lyn (이화여자대학교) Song, Seung-Yeong (이화여자대학교)
Journal
Korea Institute of Architectural Sustainable Environment and Building Systems Journal of Korean Institute of Architectural Sustainable Environment and Building Systems Vol.13 No.5 KCI Accredited Journals
Published
2019.10
Pages
303 - 314 (12page)

Usage

cover
📌
Topic
📖
Background
🔬
Method
🏆
Result
Evaluation of Condensation Prevention Performance for Apartment Built-in Furniture with Vent-type Moldings in Winter
Ask AI
Recommendations
Search
Questions

Research history (4)

  • Are you curious about the follow-up research of this article?
  • You can check more advanced research results through related academic papers or academic presentations.
  • Check the research history of this article

Abstract· Keywords

Report Errors
The purpose of this study was to evaluate the condensation prevention performance around the apartment built-in furniture applying vent-type moldings. Recently, condensation and mold problems in apartments have been growing due to the high thermal insulation and air-tightness for energy saving. The considerable amount of moisture generated by various indoor activities such as drying clothes, cooking, and taking a shower in a living space is more likely to cause condensation in apartments, and thus spaces fitted with built-in furnitures are exposed to condensation more frequently. In this study, thermal environment around the built-in furniture with vent-type moldings was measured in actual apartment from January 3 to March 5, 2019, in order to find out the location of vents effective for preventing condensation. As results, the condensation prevention performance was better when the vents were placed on both the bottom and side or both the top and bottom of the front moldings than on the back board of the built-in furniture. The proposed design will be useful to mitigate condensation in spaces fitted with built-in furnitures.

Contents

ABSTRACT
서론
붙박이장 설치 현황 및 결로 발생 현황
결로방지성능 평가 방법
통기형 몰딩 적용에 따른 붙박이장의 결로방지성능 분석
결론
References