This paper demonstrates a calibration methodology for adjusting model parameters and factors using assistant tools - python and GenOpt. In this study, a building simulation model is developed for a demonstration building for a low-energy solar house. The model is composed of a 3D model describing building architecture and HVAC system model using TRNSYS simulation program. In this study, model calibration methodology consists of two phases in order to improve the accuracy of building energy model and reduce errors of simulation results: Parameter adjustment phase and factor optimization phase. Trial and error approach is used for the first phase and GenOpt tool is employed for the second phase to improve the model performance. Based on American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE) Guideline 14 indices, the performance of the calibrated building simulation model is evaluated to obtain Normalized Mean Bias Error (NMBE)<SUB>hourly</SUB>, values within ±10% and Coefficient Variation of Root Mean Square Error (CV (RMSE))<SUB>hourly</SUB>, values within 30%. The performance indices are calculated with simulated and measured temperatures of each indoor zone and buffer tank. Daily data is used for calibrating heat pump (HP) electrical energy consumption because it is hard to fit the operating time of HP which can be different to time that heating load occurs. As a result of the calibration process, it is found that the values of NMBE<SUB>hourly </SUB>and CV (RMSE)<SUB>hourly</SUB> achieves within followings: Average indoor temperature - NMBE<SUB>hourly</SUB> is 1.2% and CV (RMSE)<SUB>hourly</SUB> is 2.2%. Buffer tank temperature NMBE<SUB>hourly</SUB> is 1.5% and CV (RMSE)<SUB>hourly</SUB> is 8.2%. And the value of NMBE<SUB>daily</SUB> and CV (RMSE)<SUB>daily</SUB> are used for HP electrical use as following: NMBE<SUB>daily</SUB> is 9.5%, CV (RMSE) is 23.4%.

목차

ABSTRACT
서론
시뮬레이션 모델 성능지표 및 캘리브레이션 선행연구
적용 대상 건물 및 시뮬레이션 모델링
모델 캘리브레이션 방법
결론 및 향후 연구 계획
References

참고문헌 (11)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2019-546-000970341