Seamless Transfer Method of MPPT for Two-stage Photovoltaic PCS
Recommendations
Search
Questions

태양광 발전 시스템의 무순단 MPPT 운전 모드 절체 기법

논문 기본 정보

Type
Academic journal
Author
Jong-Hwa Park (충남대학교) Jongmin Jo (충남대) Hyunsung An (충남대) Hanju Cha (충남대학교)
Journal
The Korean Institute of Electrical Engineers The transactions of The Korean Institute of Electrical Engineers Vol.67 No.2 KCI Accredited Journals SCOPUS
Published
2018.2
Pages
233 - 238 (6page)

Usage

cover
📌
Topic
📖
Background
🔬
Method
🏆
Result
Seamless Transfer Method of MPPT for Two-stage Photovoltaic PCS
Ask AI
Recommendations
Search
Questions

Research history (3)

  • Are you curious about the follow-up research of this article?
  • You can check more advanced research results through related academic papers or academic presentations.
  • Check the research history of this article

Abstract· Keywords

Report Errors
This paper proposes a seamless MPPT operation mode transfer method of photovoltaic system. The photovoltaic system consists of a DC-DC boost converter, a DC-Link, and a 3-level neutral point clamp (NPC) type inverter. The PV voltage fluctuates due to the output characteristics of the solar pane1 depending on the irradiation amount and the temperature. The photovoltaic system requires seamless MPPT mode transfer method that the discontinuity does not occur in order to supply the stable power to system without affecting the fluctuation of the PV voltage. MPPT operation is divided into two modes by the voltage reference. Under the condition that the PV voltage is below 650V, the DC-DC boost converter performs MPPT through duty control based on perturb & observe (P&O) method, and the inverter conducts DC-link voltage and grid current controls in synchronous reference frame. On the other hand, when the PV voltage exceeds above 650V, inverter performs MPPT in accordance with the variation of DC-link voltage control while the converter stops operating. Two MPPT operation modes is smoothly transferred through the proposed method that DC-link voltage or grid current commands are appropriately adjusted from the certain criteria. The feasibility of the MPPT operation mode transfer method is verified using a 10kW solar photovoltaic system, experimental results have good performances that the fluctuation of PV current is reduced to 100%.

Contents

Abstract
1. 서론
2. 태양광 발전 시스템의 구조
3. 태양광 발전 시스템의 MPPT 운전 모드 및 절체 기법
4. 실험 결과
4. 결론
References

References (8)

Add References

Recommendations

It is an article recommended by DBpia according to the article similarity. Check out the related articles!

Related Authors

Frequently Viewed Together

Recently viewed articles

Comments(0)

0