메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Sihyun Yoo (Korea National Sport University) Hojong Gil (Korea National Sport University) Jongbin Kim (Korea National Sport University) Jiseon Ryu (Korea National Sport University) Sukhoon Yoon (Korea National Sport University) Sang Kyoon Park (Korea National Sport University)
저널정보
대한인간공학회 대한인간공학회지 대한인간공학회지 제36권 제5호
발행연도
2017.10
수록면
395 - 409 (15page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Objective: The purpose of this study was to optimize the number and positions of foot pressure sensors using the reliability analysis of the center of pressure (COP) in smart shoes.
Background: Foot pressure can be different according to foot region, and it is important which region of the foot pressure needs to be measured.
Method: Thirty adults (age: 20.5±1.8 years, body weight: 71.4±6.5kg, height: 1.76±0.04m) participated in this study. The foot pressure data were collected using the insole of Pedar-X system (Novel GmbH, USA) with a sampling frequency of 100Hz during 1.3m/s speed walking on the treadmill (Instrumented treadmill, Bertec, USA). The intraclass correlation coefficients (ICC) were calculated between the COP positions using 4, 5, 6, 7, 8, and 99 sensors, while one-way repeated measure ANOVA was performed between the standard deviation (SD) of the COP positions.
Results: The medio-lateral (M/L) COP position using 99 sensors was positively correlated with the M/L COP positions using 6, 7, and 8 sensors; however, it was not correlated with the M/L COP positions using 4 and 5 sensors during landing phase (1~4%) (p <.05). The antero-posterior (A/P) COP position using 99 sensors was positively correlated with the A/P COP positions using 4, 5, 6, 7, and 8 sensors (p <.05). The SD of the COP position using 99 sensors was smaller than the SD of the M/L COP positions using 4, 5, 6, 7, and 8 sensors (p <.05).
Conclusion: Based on our findings, it is desirable to arrange at least 6 sensors in smart shoes.
Application: The study of optimizing the number and positions of foot pressure sensors would contribute to developing more effective smart shoes using foot pressure technology.

목차

1. Introduction
2. Method
3. Results
4. Discussion
5. Conclusion
References

참고문헌 (19)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0