Conoscopic holography, which consists of two circular polarizers and an uniaxial crystal, is incoherent holographic technology for three-dimensional display and non-contact diagnosis. In this paper, we derive the longitudinal and lateral intensities from point-source hologram made by conoscopic holography. Also, the longitudinal and lateral resolutions of conoscopic holography will be obtained from the longitudinal and lateral intensities, respectively, according to Rayleigh criterion.