메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Han-Na Kil (Chungbuk National University) Sang-Yong Eom (Chungbuk National University) Jung-Duck Park (Chung-Ang University) Toshihiro Kawamoto (University of Occupational and Environmental Health) Yong-Dae Kim (Chungbuk National University) Heon Kim (Chungbuk National University)
저널정보
한국독성학회 Toxicological Research Toxicological Research Vol.30 No.1
발행연도
2014.3
수록면
7 - 11 (5page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Malondialdehyde (MDA), used as an oxidative stress marker, is commonly assayed by measuring the thiobarbituric acid reactive substances (TBARS) using HPLC, as an indicator of the MDA concentration. Since the HPLC method, though highly specific, is time-consuming and expensive, usually it is not suitable for the rapid test in large-scale environmental epidemiologic surveys. The purpose of this study is to develop a simple and rapid method for estimating TBARS levels by using a multiple regression equation that includes TBARS levels measured with a microplate reader as an independent variable. Twelve hour urine samples were obtained from 715 subjects. The concentration of TBARS was measured at three different wavelengths (fluorescence: ?λ<SUB>-ex</SUB> 530 nm and ?λ<SUB>-em</SUB> 550 nm; ?λ<SUB>-ex</SUB> 515 nm and ?λ<SUB>-em</SUB> 553 nm; and absorbance: 532 nm) using microplate reader as well as HPLC. 500 samples were used to develop a regression equation, and the remaining 215 samples were used to evaluate the validity of the regression analysis. The induced multiple regression equation is as follows: TBARS level (?μM) = ?0.282 + 1.830 × (TBARS level measured with a microplate reader at the fluorescence wavelengths ?λ<SUB>-ex</SUB> 530 nm and ?λ<SUB>-em</SUB> 550 nm, ?μM) ?0.685 × (TBARS level measured with a microplate reader at the fluorescence wavelengths ?λ-ex 515 nm and ?λ<SUB>-em</SUB> 553 nm, ?μM) + 0.035 × (TBARS level measured with a microplate reader at the absorbance wavelength 532 nm, ?μM). The estimated TBARS levels showed a better correlation with, and are closer to, the corresponding TBARS levels measured by HPLC compared to the values obtained by the microplate method. The TBARS estimation method reported here is simple and rapid, and that is generally in concordance with HPLC measurements. This method might be a useful tool for monitoring of urinary TBARS level in environmental epidemiologic surveys with large sample sizes.

목차

INTRODUCTION
MATERIALS AND METHODS
RESULTS
DISCUSSION
REFERENCES

참고문헌 (8)

참고문헌 신청

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2015-510-001343988