메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Beom-Su Jang (Korea Atomic Energy Research Institute) Seung-Hee Park (Warren G. Magnuson Clinical Center) In Soo Shin (Korea Food and Drug Administration) Jin-Soo Maeng (Korea Food Research Institute) Chang H. Paik (Warren G. Magnuson Clinical Center)
저널정보
한국독성학회 Toxicological Research Toxicological Research Vol.29 No.1
발행연도
2013.3
수록면
21 - 25 (5page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
The selective targeting of an integrin α<SUB>v</SUB>β<SUB>3</SUB> receptor using radioligands may enable the assessment of angiogenesis and integrin α<SUB>v</SUB>β<SUB>3</SUB> receptor status in tumors. The aim of this research was to label a peptidomimetic integrin α<SUB>v</SUB>β<SUB>3</SUB> antagonist (PIA) with <SUP>99m</SUP>Tc(CO)<SUB>3</SUB> and to test its receptor targeting properties in nude mice bearing receptor-positive tumors. PIA was reacted with tris-succinimidyl aminotriacetate (TSAT) (20 mM) as a PIA per TSAT. The product, PIA-aminodiacetic acid (ADA), was radiolabeled with [<SUP>99m</SUP>Tc(CO)<SUB>3</SUB>(H<SUB>2</SUB>O)<SUB>3</SUB>]<SUP>+1</SUP>, and purified sequentially on a Sep-Pak C-18 cartridge followed by a Sep-Pak QMA anion exchange cartridge. Using gradient C-18 reverse-phase HPLC, the radiochemical purity of <SUP>99m</SUP>Tc(CO)<SUB>3</SUB>-ADA-PIA (retention time, 10.5 min) was confirmed to be > 95%. Biodistribution analysis was performed in nude mice (n = 5 per time point) bearing receptor-positive M21 human melanoma xenografts. The mice were administered <SUP>99m</SUP>Tc(CO)<SUB>3</SUB>-ADA-PIA intravenously. The animals were euthanized at 0.33, 1, and 2 hr after injection for the biodistribution study. A separate group of mice were also co-injected with 200 μg of PIA and euthanized at 1 hr to quantify tumor uptake. <SUP>99m</SUP>Tc(CO)<SUB>3</SUB>-ADA-PIA was stable in phosphate buffer for 21 hr, but at 3 and 6 hr, 7.9 and 11.5% of the radioactivity was lost as histidine, respectively. In tumor bearing mice, <SUP>99m</SUP>Tc(CO)<SUB>3</SUB>-ADA-PIA accumulated rapidly in a receptor-positive tumor with a peak uptake at 20 min, and rapid clearance from blood occurring primarily through the hepatobiliary system. At 20 min, the tumor-toblood ratio was 1.8. At 1 hr, the tumor uptake was 0.47% injected dose (ID)/g, but decreased to 0.12% ID/g when co-injected with an excess amount of PIA, indicating that accumulation was receptor mediated. These results demonstrate successful <SUP>99m</SUP>Tc labeling of a peptidomimetic integrin antagonist that accumulated in a tumor via receptor-specific binding. However, tumor uptake was very low because of low blood concentrations that likely resulted from rapid uptake of the agent into the hepatobiliary system. This study suggests that for <SUP>99m</SUP>Tc(CO)<SUB>3</SUB>-ADA-PIA to be useful as a tumor detection agent, it will be necessary to improve receptor binding affinity and increase the hydrophilicity of the product to minimize rapid hepatobiliary uptake.

목차

INTRODUCTION
MATERIALS AND METHODS
RESULTS
DISCUSSION
REFERENCES

참고문헌 (0)

참고문헌 신청

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2014-510-003159919