메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
이진숙 (충남대학교) 김병수 (BEMS 컨설팅) 한원탁 (충남대학교)
저널정보
대한건축학회 대한건축학회 논문집 - 계획계 大韓建築學會論文集 計劃系 第27卷 第8號
발행연도
2011.8
수록면
271 - 278 (8page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
This study intends to ensure the data of influence of which the area, color temperature and luminance of LED luminaires is exercised to discomfort glare. The experiment was progressed in 5 steps.
1)The Mock-up was produced to install the LED luminaires by area which can adjust the color temperature and luminance. 2)We measured the physical properties by experimental variable. 3)We made a comparative analysis of discomfort glare according to the area of LED luminaires. 4)We made a comparative analysis of discomfort glare according to the color temperature of LED luminaires. 5)We made a comparative analysis of discomfort glare according to the luminance of LED luminaires. The experimental result is as following. 1)When the luminance is the same in all the color temperature, the discomfort glare is also increased according as the area of LED luminaires id increased. Also the difference of discomfort glare according to the area was made higher with the higher luminance. And the change of discomfort glare is less according to the area of color temperature of 3300K. 2)The discomfort glare according to the change of color temperature in all the area of luminaires was shown that the discomfort glare was increased with the higher color temperature . The change of discomfort glare is increased with the higher luminance. Also the luminaires with area of 300㎜×300㎜ has less change of discomfort glare according to thecolor temperature in comparison of the other area of luminaires. 3)The discomfort glare according to the change of luminance is also increased with the luminance increased in all the area of luminaires. Also, The change of discomfort glare is increased according to the luminance with the increased area of luminaires. 4)The LED luminaires has the discomfort glare increased with the lower background luminance(with the higher luminance contrast). 5)As much more number of luminous source are shown from table 1 to Table 3, the other accorded variable was highly evaluated for the discomfort glare in Table3.

목차

Abstract
1. 서론
2. 실험 진행
3. 실험 결과 분석
4. 결론
참고문헌

참고문헌 (8)

참고문헌 신청

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2013-540-000329222