High rise buildings vibrate sensitively by the strong wind with reduction of weight and damping ratio recently. As increased the high rise buildings, a lot of people appeal the problems in serviceability caused by intensive vibration of building when strong wind has passed. In this paper, the active mass damper (AMD) which adopts the H∞ control algorithm is designed and applied to a exist building structure. This may be the first full-scale application of AMD to the existing building in the world. Two AMDs, which have 20 ton mass and 10 ton mass for x-axis and y-axis, respectively, are installed on the roof of the builidng structure, and those AMDs are design to control not only transverse response but also even torsion responses. In order to verify the performance of the AMD system, the controlled responses of the building structure are measured during a typhoon passes through the Korean Peninsula and compared with the uncontrolled responses obtained by a numerical simulation.