오류제보하기
While the recent high demand for mega-tall buildings have urged to develop high-performance and high-strength steels, the requirements for steel for architectural structure performance have strengthened as the engineers recognize the potential damage of an earthquake on a tall building. A 600㎫ class steel has emerged to meet these needs, and many studies are currently developing its practical applications on civil engineering and mega-tall buildings. Data on the horizontal force behaviors of structure using the new steel, however, are still insufficient. Especially concerning its toughness, there is an urgent need for the design data, comparing the plastic strain ratios of column-to-beam connections using high-strength steel and regular steel. As one of the first studies on the behavior of a column-to-beam connection using 600㎫ (TMC) class steel, this thesis analyzes its structural performance by conducting a structural test for seismic resistance on a full scale column-to-beam welded connection with non-scallop and recommended scallop details.

목차

Abstract
1. 서론
2. 내진성능 지표
3. 실험계획 및 방법
4. 실험 결과 및 분석
5. 접합부의 인성평가
6. 결론