Recently, mixers are being widely used in the water purification plant in order to increase the filtration efficiency. The mixer normally consists of impeller, shaft, hub, reduction gear, and the driving motor. It is one of the key design issues to confirm that the vibration caused by the rotation of the shaft should not coincide with the natural vibration frequency of the shaft itself. The vibration characteristics of the hydrofoil type mixer, which is the most widely used in real plants are evaluated through the finite element modeling and verified by experiment using the mock-up facility. The fundamental natural frequency of the mixer's shaft is found to be around 1.8 ㎐ which showed in good agreement with the experiment. The higher natural frequencies to the 2nd, 3rd, and 4th modes are also verified by the experiment. Thus the developed model is to be utilized for the structural design of the real mixer system.