It is necessary to strengthen the insulation of building envelopes for reducting building heating load for evergy saving in building sector. The aim of this paper is to induce and study an hourly heat flow theory in inside and outside insulated constructions with response factors analysis, to compare and evalulate on thermal performance an hourly natural temperature, heated temperature, and heating load in above-mentioned contructions with computer simulation. The results of the study can be summarized as follows. That is to say; daily natural range of temperature each shows 10.1'c and 2.9'c, daily heating range of temperature with normal control heating system each hows 5.1'c and 9.1c, heating hours each hows 9 hours and 8 hours and heating energy saving percentage each shows 121% and 100 %